LiverMRDoc reached liver MRI judgments faster in China's review

In the maker's trial that China's CMDE reviewed, judgments on liver MRI took a median of 7.47 minutes with LiverMRDoc, against 9.45 minutes for an expert panel.

  • Not rated an organization

    The time saving was measured on stored images in the maker's pre-market trial, and the report gives no result from use after approval.

Depth runs from 1, a convenience or time saved, to 5, a life or a livelihood preserved.

Status
Intended benefit.
Evidence

found, the grade of this recordstudiedreportedclaimed

An independent regulatory document supports the benefit.

Compared with

The expert panel that set the reference standard, reading the same 490 cases. Measured.

Without the system
median 9.45min for the expert panel
With it
median 7.47min with the software
The system’s part
Not isolated. The trial compared the software's results with target values and its time with that of the expert panel that set the reference standard. The panel and the software group differ in more than the use of the software, so the time saving is not isolated to it. The report says that the product uses deep learning.
Not yet checked
LimitsCosts and harmsLearns from dataLater outcome
Benefit type
Reduced Task Time
System
LiverMRDoc (肝脏局灶性病变MR图像辅助分诊软件)
Made by
Yukun (Beijing) Network Technology Co., Ltd. (语坤(北京)网络科技有限公司)
Used by
Yukun (Beijing) Network Technology (retrospective registration trial with 490 cases at two hospitals)
Where
Beijing Friendship Hospital of Capital Medical University in Beijing and Ningbo Hwa Mei Hospital of the University of Chinese Academy of Sciences in Ningbo, China
Stage
Tested in a laboratory
Date
, when the source was published
Kind
Aggregate result
Broad benefit
Identifying Objects, Actions, and Events, Organizing, Planning, and Prioritizing Work
Collections
Scrutiny and findings
Last revised
1 November 2026

Sources

  1. Regulatory document, by authors with no tie to the system.

    Center for Medical Device Evaluation (CMDE), National Medical Products Administration, China. 医疗器械产品注册技术审评报告:肝脏局灶性病变MR图像辅助分诊软件 (technical review report for the registration of focal liver lesion MR image triage-aid software), acceptance no. CQZ2201476, applicant 语坤(北京)网络科技有限公司. 22 November 2023. Section 三、临床评价概述 (clinical evaluation).

    试验组与专家组判定时间,FAS分析集,软件判定时间中位数 7.47min,专家组判定时间中位数 9.45min,软件判定时间小于专家组判定时间,P<0.0001,两组差值有统计学意义

Details

AI system

Reported configuration

Release 2.0 (full version 2.0.1.001)

Workflow

The software extracted liver segments from MR images with deep learning and detected suspected focal lesions in them. It listed the cases with suspected lesions, and doctors could add, delete or edit lesions before a text report was made. An expert panel's results served as the reference standard.

Follow-up

Conditions for replication

Patients are adults, and the lesions are 5 mm or larger. Trained doctors use the results as a reference and do not base a clinical decision on the software alone.

Entry details

Sector

Healthcare.

Purpose

Yukun (Beijing) Network Technology built LiverMRDoc to help trained doctors triage suspected focal liver lesions of 5 mm or more in adults on MRI.

30 more questions not yet checked

model, provider, role, configuration, inputs and outputs, autonomy, human oversight, AI contribution, beneficiaries, reach, distribution and access, duration, every measurement question, every money question, ownership and control, dependencies, cross-border connections, geopolitical implications, replication attempts, availability, institutional decision, grounds, action and result, success criterion, every evidence question, observed or intended, alternative assessments, related entries, other identifiers, category mappings.

Cite this record

Peter H. Vartanian. (2026). LiverMRDoc reached liver MRI judgments faster in China's review (AIBD-1075). Artificial Intelligence Benefits Database, edition of 1 November 2026. https://petervartanian.xyz/aibd/records/AIBD-1075.html (archived at https://doi.org/10.7910/DVN/AADSII, version 7.0)

BibTeX Data Field definitions