Benefits
- Benefit
-
Their sensitivity rose from 82.0% to 91.4%
Awaiting review
- Outcome identifiers
-
Unresolved
Not reviewedUnresolved
- Category
-
Improved Task Accuracy
Awaiting review
- Status
-
Reported benefit
Awaiting review
- Beneficiary groups
-
Organizations.
Awaiting review
- Beneficiaries
-
Unresolved
Not reviewedUnresolved
- Reach
-
Unresolved
Not reviewedUnresolved
- Distribution and access
-
Unresolved
Not reviewedUnresolved
- Duration
-
Unresolved
Not reviewedUnresolved
- Expected?
-
Yes
Awaiting review
- Costs and harms
-
Unresolved
Not reviewedUnresolved
AI system
- System
-
DermaSensor
Awaiting review
- Model
-
This is an explicit unresolved assignment: the sources on record do not settle this question.
Not reviewedUnresolved
- Release
-
Unresolved
Not reviewedUnresolved
- Provider
-
Unresolved
Not reviewedUnresolved
- Role
-
Unresolved
Not reviewedUnresolved
- Configuration
-
Unresolved
Not reviewedUnresolved
- Inputs and outputs
-
Unresolved
Not reviewedUnresolved
- Autonomy
-
Unresolved
Not reviewedUnresolved
- Workflow
-
Physicians applied the device to lesions they already found suspicious. Physicians used the output as a second read after their own assessment.
Awaiting review
- Human oversight
-
Unresolved
Not reviewedUnresolved
- Relation to AI
-
In the reader study each physician judged every lesion with and without the device output, so the change in sensitivity is attributed to the device.
Awaiting review
- AI contribution
-
In the reader study each physician judged every lesion with and without the device output, so the change in sensitivity is attributed to the device.
Awaiting review
Measurement
- Studies
-
Study 1: quasi-experimental. Study 2: other. [1]
Fully reviewedDetails: supporting details for Studies
Review date: 29 October 2026.
Sources: [1]
- Study design
-
Study 1: quasi-experimental. Study 2: other. [1]
Fully reviewedDetails: supporting details for Study design
Review date: 29 October 2026.
Sources: [1]
- Measurement
-
Study 1: Multi-reader study; each lesion image viewed with and without device output in random order; refer or do not refer decision. Study 2: Prospective blinded standalone accuracy study against biopsy, with physician assessment on the same lesions. [1]
Fully reviewedDetails: supporting details for Measurement
Review date: 29 October 2026.
Sources: [1]
- Setting and sample
-
Study 1: 108 internal medicine or family practice physicians; 25 malignant and 25 benign lesions. Study 2: 1,005 patients, 1,579 lesions, 22 sites in the US and Australia. [1]
Fully reviewedDetails: supporting details for Setting and sample
Review date: 29 October 2026.
Sources: [1]
- Measures
-
Study 1: Referral sensitivity and specificity. Study 2: Sensitivity and specificity. [1]
Fully reviewedDetails: supporting details for Measures
Review date: 29 October 2026.
Sources: [1]
- Comparison
-
Study 1: Unaided reads by the same physicians. Study 2: Primary care physicians on the same lesions. [1]
Fully reviewedDetails: supporting details for Comparison
Review date: 29 October 2026.
Sources: [1]
- Results
-
Study 1: Sensitivity 82.0% to 91.4%; specificity 44.2% to 32.4%. Study 2: Sensitivity 95.5% against 83.0%; specificity 20.7% against 54.2%. [1]
Fully reviewedDetails: supporting details for Results
Review date: 29 October 2026.
Sources: [1]
- Additional value from AI
-
Study 1: AUROC 0.708 to 0.762. Study 2: Not a with-and-without comparison. [1]
Fully reviewedDetails: supporting details for Additional value from AI
Review date: 29 October 2026.
Sources: [1]
- Limitations
-
Study 1: Image-based reads; lower specificity; limited data for Fitzpatrick IV to VI. Study 2: Low specificity; under-40 sensitivity below 90%. [1]
Fully reviewedDetails: supporting details for Limitations
Review date: 29 October 2026.
Sources: [1]
Money
- Kind of value
-
The kind of monetary value is unclear.
Not reviewedUnresolved
- Amount
-
The monetary value is not established.
Not reviewedUnresolved
- Currency and prices
-
The currency and price basis are unclear.
Not reviewedUnresolved
- Period and unit
-
The period and unit of the monetary estimate are unclear.
Not reviewedUnresolved
- Realization
-
Whether the monetary value was realized is unclear.
Not reviewedUnresolved
- Recipients and payers
-
The recipients and payers are unclear.
Not reviewedUnresolved
- Gross or net
-
Whether the monetary figure includes costs is unclear.
Not reviewedUnresolved
- Included costs
-
The costs included in the estimate are unclear.
Not reviewedUnresolved
- Comparison
-
The financial comparison is not established.
Not reviewedUnresolved
- Method
-
The method used to calculate monetary value is unclear.
Not reviewedUnresolved
- Return and payback
-
The return on investment or payback period is not established.
Not reviewedUnresolved
People and places
- Participants
-
Developer: DermaSensor, Inc. Operator: Primary care sites in the DERM-SUCCESS study.
Awaiting review
- Jurisdictions
-
Benefit: Twenty-two sites in the
United States and
Australia. Developer:
United States. Operator:
United States;
Australia.Awaiting review
- Ownership and control
-
Unresolved
Not reviewedUnresolved
- Dependencies
-
Unresolved
Not reviewedUnresolved
- Cross-border connections
-
Unresolved
Not reviewedUnresolved
- Geopolitical implications
-
The geopolitical implications are unclear.
Not reviewedUnresolved
Follow-up
- Conditions for replication
-
The patient is aged 40 or older. A dermatologist makes the final management decision after referral.
Awaiting review
- Replication attempts
-
Unresolved
Not reviewedUnresolved
- Later findings
-
Unresolved
Not reviewedUnresolved
- Availability
-
Unresolved
Not reviewedUnresolved
- Institutional decision
-
A relevant institutional decision has not been established.
Not reviewedUnresolved
- Grounds
-
The grounds for an institutional decision are unclear.
Not reviewedUnresolved
- Action and result
-
The result of an institutional decision is not established.
Not reviewedUnresolved
- Success criterion
-
The criterion for a successful institutional decision is unclear.
Not reviewedUnresolved
Evidence
- Source numbers
-
AIBD-0630-source-0001
Awaiting review
- Citations
-
Numbered references below.
Awaiting review
- Language
-
Unresolved
Not reviewedUnresolved
- Source relationships
-
Independent
Awaiting review
- Original evidence
-
Unresolved
Not reviewedUnresolved
- Access and versions
-
Unresolved
Not reviewedUnresolved
- Supported findings
-
Unresolved
Not reviewedUnresolved
- Evidence links
-
Unresolved
Not reviewedUnresolved
- Evidence strength
-
Found by a regulator. Sources: one independent regulatory document. The cited evidence includes no independent study or report. [1]
Fully reviewedDetails: supporting details for Evidence strength
Review date: 29 October 2026.
Sources: [1]
- Missing evidence
-
Unresolved
Not reviewedUnresolved
Grades
- Assessed benefits
-
Organizations.
Awaiting review
- Depth
-
Organizations: 2.
Awaiting review
- Reasons
-
Organizations: Primary care physicians aided by the device reached 91.4% sensitivity for skin cancer referral against 82.0% unaided.
Awaiting review
- Observed or intended
-
Unresolved
Not reviewedUnresolved
- Rubric
-
Unresolved
Not reviewedUnresolved
- Assessor and date
-
Unresolved
Not reviewedUnresolved
- Alternative assessments
-
Unresolved
Not reviewedUnresolved
- Fill
-
Found by a regulator
Awaiting review
Entry details
- Kind
-
The case describes an evaluation or a study. A regulatory review of a pivotal study and reader studies. [1]
Fully reviewedDetails: supporting details for Kind
Review date: 29 October 2026.
Sources: [1]
- Related entries
-
No incident in the AI Incident Database snapshot of 26 October 2026 concerns the same kind of system harming the same kind of stakeholder.
Partly reviewedUnresolvedDetails: supporting details for Related entries
Compared with the incidents in the AI Incident Database snapshot of 26 October 2026.
- Field
-
Healthcare.
Awaiting review
- Purpose
-
DermaSensor was built to help physicians who are not dermatologists decide whether to refer a suspicious skin lesion. Better referral sensitivity is that purpose.
Awaiting review
- Dates
-
Source published: 12 January 2024. Updated: 29 October 2026.
Awaiting review
- Stage
-
The system was used in a pilot. A prospective pivotal study at 22 primary care sites plus reader studies before authorization. [1]
Fully reviewedDetails: supporting details for Stage
Review date: 29 October 2026.
Sources: [1]
- Version
-
SHA-256: 638aa09a08a7…
Awaiting reviewDetails: supporting details for Version
SHA-256 of the public case, its assessments, and its displayed answers and notes, excluding its own identifier and the derived coverage summary.
References
- Other identifiers
-
Unresolved
Not reviewedUnresolved
- Category mappings
-
Unresolved
Not reviewedUnresolved
- Citable summary
-
Unresolved
Not reviewedUnresolved
- Revisions
-
1 revision. Latest: 29 October 2026.
Awaiting review
Sources
-
Regulatory document Independent author
U.S. Food and Drug Administration, Center for Devices and Radiological Health. De Novo classification request for DermaSensor (DEN230008): decision summary. Granted 2024-01-12.
The main benefit of the DermaSensor device is the demonstrated ability to improve the management decision of PCPs in the intended use population.
Collections: Scrutiny and findings, Cross-border cases.