Benefits
- Benefit
-
An adenoma detection rate of 55.1% with GI Genius against 42.0% with standard colonoscopy
Awaiting review
- Outcome identifiers
-
Unresolved
Not reviewedUnresolved
- Category
-
Improved Task Accuracy
Awaiting review
- Status
-
Reported benefit
Awaiting review
- Beneficiary groups
-
People. Organizations.
Awaiting review
- Beneficiaries
-
Unresolved
Not reviewedUnresolved
- Reach
-
Unresolved
Not reviewedUnresolved
- Distribution and access
-
Unresolved
Not reviewedUnresolved
- Duration
-
Unresolved
Not reviewedUnresolved
- Expected?
-
Yes
Awaiting review
- Costs and harms
-
Unresolved
Not reviewedUnresolved
AI system
- System
-
GI Genius
Awaiting review
- Model
-
This is an explicit unresolved assignment: the sources on record do not settle this question.
Not reviewedUnresolved
- Release
-
Unresolved
Not reviewedUnresolved
- Provider
-
Unresolved
Not reviewedUnresolved
- Role
-
Unresolved
Not reviewedUnresolved
- Configuration
-
Unresolved
Not reviewedUnresolved
- Inputs and outputs
-
Unresolved
Not reviewedUnresolved
- Autonomy
-
Unresolved
Not reviewedUnresolved
- Workflow
-
Endoscopists with an adenoma detection rate of 25 to 40% used the program during white-light colonoscopy. A minimum withdrawal time of six minutes was required. Histology confirmed each lesion.
Awaiting review
- Human oversight
-
Unresolved
Not reviewedUnresolved
- Relation to AI
-
Patients were randomized to colonoscopy with or without GI Genius, performed by the same endoscopists, so the trial isolates the contribution of the program.
Awaiting review
- AI contribution
-
Patients were randomized to colonoscopy with or without GI Genius, performed by the same endoscopists, so the trial isolates the contribution of the program.
Awaiting review
Measurement
- Studies
-
Randomized. [2]
Fully reviewedDetails: supporting details for Studies
Review date: 29 October 2026.
Sources: [2]
- Study design
-
Randomized. [2]
Fully reviewedDetails: supporting details for Study design
Review date: 29 October 2026.
Sources: [2]
- Measurement
-
Randomized 1:1 multicenter trial with histology as reference; FDA reanalysis in low-risk patients. [2]
Fully reviewedDetails: supporting details for Measurement
Review date: 29 October 2026.
Sources: [2]
- Setting and sample
-
700 patients at three Italian hospitals; 263 low-risk patients in the FDA analysis; six endoscopists. [2]
Fully reviewedDetails: supporting details for Setting and sample
Review date: 29 October 2026.
Sources: [2]
- Measures
-
Adenoma detection rate and adenomas per colonoscopy. [2]
Fully reviewedDetails: supporting details for Measures
Review date: 29 October 2026.
Sources: [2]
- Comparison
-
Standard colonoscopy without the program. [2]
Fully reviewedDetails: supporting details for Comparison
Review date: 29 October 2026.
Sources: [2]
- Results
-
ADR 55.1% against 42.0%; APC 0.81 against 0.57. [2]
Fully reviewedDetails: supporting details for Results
Review date: 29 October 2026.
Sources: [2]
- Additional value from AI
-
Adjusted ADR difference of 13.1 percentage points. [2]
Fully reviewedDetails: supporting details for Additional value from AI
Review date: 29 October 2026.
Sources: [2]
- Limitations
-
Limited patient diversity; six endoscopists in Italy; cancer outcomes not measured. [2]
Fully reviewedDetails: supporting details for Limitations
Review date: 29 October 2026.
Sources: [2]
Money
- Kind of value
-
The kind of monetary value is unclear.
Not reviewedUnresolved
- Amount
-
The monetary value is not established.
Not reviewedUnresolved
- Currency and prices
-
The currency and price basis are unclear.
Not reviewedUnresolved
- Period and unit
-
The period and unit of the monetary estimate are unclear.
Not reviewedUnresolved
- Realization
-
Whether the monetary value was realized is unclear.
Not reviewedUnresolved
- Recipients and payers
-
The recipients and payers are unclear.
Not reviewedUnresolved
- Gross or net
-
Whether the monetary figure includes costs is unclear.
Not reviewedUnresolved
- Included costs
-
The costs included in the estimate are unclear.
Not reviewedUnresolved
- Comparison
-
The financial comparison is not established.
Not reviewedUnresolved
- Method
-
The method used to calculate monetary value is unclear.
Not reviewedUnresolved
- Return and payback
-
The return on investment or payback period is not established.
Not reviewedUnresolved
People and places
- Participants
-
Developer: Cosmo Artificial Intelligence - AI, Ltd. Operator: Humanitas Research Hospital, Nuovo Regina Margherita Hospital and Valduce Hospital (AID trial).
Awaiting review
- Jurisdictions
-
Benefit: Milan, Rome and Como,
Italy. Developer:
Ireland. Operator:
Italy.Awaiting review
- Ownership and control
-
Unresolved
Not reviewedUnresolved
- Dependencies
-
Unresolved
Not reviewedUnresolved
- Cross-border connections
-
Unresolved
Not reviewedUnresolved
- Geopolitical implications
-
The geopolitical implications are unclear.
Not reviewedUnresolved
Follow-up
- Conditions for replication
-
The program runs with standard white-light endoscopy. Endoscopists use the marks as an aid and keep inspecting the whole colon.
Awaiting review
- Replication attempts
-
Unresolved
Not reviewedUnresolved
- Later findings
-
Unresolved
Not reviewedUnresolved
- Availability
-
Unresolved
Not reviewedUnresolved
- Institutional decision
-
A relevant institutional decision has not been established.
Not reviewedUnresolved
- Grounds
-
The grounds for an institutional decision are unclear.
Not reviewedUnresolved
- Action and result
-
The result of an institutional decision is not established.
Not reviewedUnresolved
- Success criterion
-
The criterion for a successful institutional decision is unclear.
Not reviewedUnresolved
Evidence
- Source numbers
-
AIBD-0623-source-0001–0002
Awaiting review
- Citations
-
Numbered references below.
Awaiting review
- Language
-
Unresolved
Not reviewedUnresolved
- Source relationships
-
Independent, Relationship unreported
Awaiting review
- Original evidence
-
Unresolved
Not reviewedUnresolved
- Access and versions
-
Unresolved
Not reviewedUnresolved
- Supported findings
-
Unresolved
Not reviewedUnresolved
- Evidence links
-
Unresolved
Not reviewedUnresolved
- Evidence strength
-
Found by a regulator. Sources: one independent regulatory document and one peer-reviewed study with authorship relationship unassessed. The cited evidence includes no independent study or report. [1] [2]
- Missing evidence
-
Unresolved
Not reviewedUnresolved
Grades
- Assessed benefits
-
People. Organizations.
Awaiting review
- Depth
-
People: 2. Organizations: 2.
Awaiting review
- Reasons
-
People: Patients in the GI Genius arm had at least one adenoma found in 55.1% of procedures against 42.0% in the standard arm. Organizations: Endoscopists found 0.81 adenomas per colonoscopy with the program against 0.57 without it.
Awaiting review
- Observed or intended
-
Unresolved
Not reviewedUnresolved
- Rubric
-
Unresolved
Not reviewedUnresolved
- Assessor and date
-
Unresolved
Not reviewedUnresolved
- Alternative assessments
-
Unresolved
Not reviewedUnresolved
- Fill
-
Found by a regulator
Awaiting review
Entry details
- Kind
-
The case describes an evaluation or a study. A regulatory review of a randomized controlled trial. [2]
Fully reviewedDetails: supporting details for Kind
Review date: 29 October 2026.
Sources: [2]
- Related entries
-
No incident in the AI Incident Database snapshot of 26 October 2026 concerns the same kind of system harming the same kind of stakeholder.
Partly reviewedUnresolvedDetails: supporting details for Related entries
Compared with the incidents in the AI Incident Database snapshot of 26 October 2026.
- Field
-
Healthcare.
Awaiting review
- Purpose
-
GI Genius was built to help endoscopists detect colonic lesions such as polyps and adenomas in real time. Higher adenoma detection is that purpose.
Awaiting review
- Dates
-
Observed: November 2019. Updated: 29 October 2026.
Awaiting review
- Stage
-
The system was used in a pilot. A randomized trial in three hospitals before US authorization. [2]
Fully reviewedDetails: supporting details for Stage
Review date: 29 October 2026.
Sources: [2]
- Version
-
SHA-256: 4595da4a3cdc…
Awaiting reviewDetails: supporting details for Version
SHA-256 of the public case, its assessments, and its displayed answers and notes, excluding its own identifier and the derived coverage summary.
References
- Other identifiers
-
Unresolved
Not reviewedUnresolved
- Category mappings
-
Unresolved
Not reviewedUnresolved
- Citable summary
-
Unresolved
Not reviewedUnresolved
- Revisions
-
1 revision. Latest: 29 October 2026.
Awaiting review
Sources
-
Peer-reviewed study Authorship unassessed
The ADR was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk [RR], 1.30; 95% confidence interval [CI], 1.14-1.45).
-
Regulatory document Independent author
U.S. Food and Drug Administration, Center for Devices and Radiological Health. De Novo classification request for GI Genius (DEN200055): decision summary. Granted 2021-04-09.
The GI Genius procedures had an ADR* of 55.1% and the standard colonoscopy procedures had an ADR* of 42.0%.
Collections: Scrutiny and findings, Cross-border cases.