Apple Watch ECG T-wave leads a 76-year-old to quadruple bypass

Koster et al. (EHJ Case Reports, 30 Jan 2024): a patient-initiated lead-I watch ECG showed a negative T-wave normalizing after 22 min; exercise test, CT and angiography found 3-vessel disease; CABG.

AI system

System

Apple Watch ECG app (single lead-I recording; its rhythm classifier is not mentioned in the report)

Model

Not assessed

Release

Not assessed

Application developer

Apple

Role

Not assessed

Configuration

Not assessed

Inputs and outputs

Not assessed

Autonomy

Not assessed

Workflow

A wearer who records a watch ECG right after exercise and looks at the waveform, not only the rhythm label. A cardiologist willing to investigate a watch trace in an asymptomatic patient. Exercise testing, CT, angiography and perfusion imaging to confirm and grade the disease.

Human oversight

Not assessed

Relation to AI

The watch recorded a 30-second lead-I trace at the wearer's initiative. The report gives no classification result from the app. The negative T-wave was noticed by the patient and interpreted by cardiologists, who ordered the exercise test, imaging and surgery. No machine-learning output contributed to the finding as described. The single source is an independent peer-reviewed case report. No maker material was used.

AI contribution

The watch recorded a 30-second lead-I trace at the wearer's initiative. The report gives no classification result from the app. The negative T-wave was noticed by the patient and interpreted by cardiologists, who ordered the exercise test, imaging and surgery. No machine-learning output contributed to the finding as described. The single source is an independent peer-reviewed case report. No maker material was used.

Benefits

Outcome identifiers

Not assessed

Benefit

he received four bypass grafts; recovery was uneventful

Category

Improved Physical Health

Status

Not assessed

Beneficiary groups

People.

Beneficiaries

Not assessed

Reach

Not assessed

Distribution and access

Not assessed

Duration

Not assessed

Expected?

No

Costs and harms

Not assessed

Measurement

Studies

Not assessed

Study design

Not assessed

Measurement

Not assessed

Setting and sample

Not assessed

Measures

he received four bypass grafts; recovery was uneventful

Comparison

the cardiologist's resting 12-lead ECG and physical examination

Results

Reference: A standard ECG was completely normal, as was physical examination. Result: he noticed immediately after exercise, a negative T-wave that became more prominent in ∼7 min, then slowly returned back to a normal positive T-wave after 22 min.

Additional value from AI

Not assessed

Limitations

Not assessed

Denominators

Not assessed

Materials for replication

Not assessed

Money

Kind of value

Not assessed

Amount

Not assessed

Currency and prices

Not assessed

Period and unit

Not assessed

Realization

Not assessed

Recipients and payers

Not assessed

Gross or net

Not assessed

Included costs

Not assessed

Comparison

Not assessed

Method

Not assessed

Return and payback

Not assessed

People and places

Participants

Developer: Apple.

Jurisdictions

Benefit: Amsterdam, the Netherlands. Developer: United States.

Ownership and control

Not assessed

Dependencies

Not assessed

Cross-border connections

Not assessed

Geopolitical implications

Not assessed

Follow-up

Conditions for replication

The lead-I trace reproduces T-wave changes faithfully, which the authors say appeared accurate though frequency characteristics are undocumented. Ischemia that shows in lead I, which the authors call not ideal for the purpose. Tolerance of false positives and investigation cascades, which the authors flag as unstudied.

Replication attempts

Not assessed

Later findings

The paper's own 11-week postoperative exercise ECG (normal) is part of the first report; nothing published later about the patient was found.

Availability

Not assessed

Institutional decision

Not assessed

Grounds

Not assessed

Action and result

Not assessed

Success criterion

Not assessed

Evidence

Source numbers

AIBD-0301-source-0001–0004

Citations

Numbered references below.

Language

Not assessed

Source relationships

Independent

Original evidence

Not assessed

Access and versions

Not assessed

Supported findings

Not assessed

Evidence strength

Not assessed

Missing evidence

Not assessed

Grades

Assessed benefits

People.

Depth

People: 3.

Reasons

People: Silent, extensive, reversible ischemia from three-vessel disease was found and treated with quadruple bypass in an asymptomatic man. The authors' learning point is that such ischemia can end in exercise-induced sudden death. The counterfactual is not established.

Observed or intended

Not assessed

Rubric

Not assessed

Assessor and date

Not assessed

Alternative assessments

Not assessed

Fill

Independently studied

Entry details

Kind

Not assessed

Field

Healthcare (cardiology). Consumer wearables.

Purpose

The ECG app is built to record a single-lead ECG and classify atrial fibrillation. Using the trace to spot exercise-induced ischemia is, as the authors say, not endorsed by Apple.

Dates

Date basis unassessed: 2024 (precision unassessed). Updated: 21 October 2026.

Stage

Not assessed

Version

SHA-256: 7f02698d60bc…

References

Other identifiers

Not assessed

Category mappings

Not assessed

Brief

Not assessed

Revisions

5 revisions. Latest: 21 October 2026.

Sources

  1. Case report Independent author

    Koster RW, de Winter RJ, Verberne HJ, Spijkerboer AM, Chamuleau SA (2024). Severe silent ischaemia detected with an Apple Watch in the home setting: a case report. European Heart Journal - Case Reports 8(2):ytae043 (PMC10872691).