AI system
- System
-
Fitbit Charge 3 estimated oxygen variation (EOV) and resting heart rate, with investigator-defined signal thresholds
- Model
-
Not assessed
- Release
-
Exact release not established.
- Application developer
-
Fitbit (device and EOV algorithm); Kanazawa University investigators (signal definitions) - Role
-
Not assessed
- Configuration
-
The participant used a Fitbit Charge 3.
- Inputs and outputs
-
Not assessed
- Autonomy
-
Not assessed
- Workflow
-
A Fitbit Charge 3 worn for 30 days by patients with PCR-confirmed COVID-19, giving EOV and resting heart rate. An investigator-defined high-EOV signal (a significant dip and recovery of the oxygen level within the index period) reviewed by the study team. Weekly phone calls to discharged patients and access to portable polysomnography.
- Human oversight
-
Not assessed
- Relation to AI
-
The device produced the EOV values. The investigators' own rule flagged high signals, and clinicians decided to order polysomnography for the sleep-apnea patient. The paper does not say whether Fitbit's EOV estimation uses machine learning and notes the functions were not approved as a medical device. The COVID-19 prediction figures were computed after the outcomes were known, not from alerts acted on in real time.
- AI contribution
-
The device produced the EOV values. The investigators' own rule flagged high signals, and clinicians decided to order polysomnography for the sleep-apnea patient. The paper does not say whether Fitbit's EOV estimation uses machine learning and notes the functions were not approved as a medical device. The COVID-19 prediction figures were computed after the outcomes were known, not from alerts acted on in real time.
Benefits
- Outcome identifiers
-
Not assessed
- Benefit
-
EOV signals preceded four of five analyzed cases (sensitivity 80%, specificity 90%)
- Category
-
Improved Physical Health
- Status
-
Not assessed
- Beneficiary groups
-
People. Organizations.
- Beneficiaries
-
Not assessed
- Reach
-
Not assessed
- Distribution and access
-
Not assessed
- Duration
-
Not assessed
- Expected?
-
No
- Costs and harms
-
Not assessed
Measurement
- Studies
-
Not assessed
- Study design
-
Not assessed
- Measurement
-
Not assessed
- Setting and sample
-
Not assessed
- Measures
-
EOV signals preceded four of five analyzed cases (sensitivity 80%, specificity 90%)
- Comparison
-
high resting-heart-rate (RHR) signals from the same Fitbit data
- Results
-
Reference: the sensitivity and specificity of high RHR signals were 50% and 80%, respectively. Result: 4 out of 5 cases (sensitivity=80%, specificity=90%).
- Additional value from AI
-
Not assessed
- Limitations
-
Not assessed
- Denominators
-
Not assessed
- Materials for replication
-
Not assessed
Money
- Kind of value
-
Not assessed
- Amount
-
Not assessed
- Currency and prices
-
Not assessed
- Period and unit
-
Not assessed
- Realization
-
Not assessed
- Recipients and payers
-
Not assessed
- Gross or net
-
Not assessed
- Included costs
-
Not assessed
- Comparison
-
Not assessed
- Method
-
Not assessed
- Return and payback
-
Not assessed
People and places
- Participants
-
Developer:
Fitbit (device and EOV algorithm); Kanazawa University investigators (signal definitions). Operator: Kanazawa University and JCHO Kanazawa Hospital (DEXTERITY pilot, UMIN000041421). - Jurisdictions
-
Benefit: Kanazawa,
Japan. Developer:
United States. Operator:
Japan. - Ownership and control
-
Not assessed
- Dependencies
-
Not assessed
- Cross-border connections
-
Not assessed
- Geopolitical implications
-
Not assessed
Follow-up
- Conditions for replication
-
Patients can pair the device with a smartphone app (elderly patients unable to use a smartphone were not enrolled). Enough baseline data to separate abnormal signals from normal variation, which the authors list as lacking in the 30-day window.
- Replication attempts
-
Not assessed
- Later findings
-
No later DEXTERITY publication and no follow-up on patient JCHO-023 was found in the cited paper.
- Availability
-
Not assessed
- Institutional decision
-
Not assessed
- Grounds
-
Not assessed
- Action and result
-
Not assessed
- Success criterion
-
Not assessed
Evidence
- Source numbers
-
AIBD-0294-source-0001–0004
- Citations
-
Numbered references below.
- Language
-
Not assessed
- Source relationships
-
Developer
- Original evidence
-
Not assessed
- Access and versions
-
Not assessed
- Supported findings
-
Not assessed
- Evidence links
-
Not assessed
- Evidence strength
-
Not assessed
- Missing evidence
-
Not assessed
Grades
- Assessed benefits
-
People. Organizations.
- Depth
-
People: 1. Organizations: Not assessed.
- Reasons
-
People: One man received a diagnosis of severe obstructive sleep apnea (3% ODI 33.6/h) from an incidental wearable signal. The paper reports no treatment or follow-up for him. Organizations: The 80% sensitivity for predicting exacerbation is a retrospective pilot result on five events, which the authors say is too small to generalize. No live alerting or changed care is documented.
- Observed or intended
-
Not assessed
- Rubric
-
Not assessed
- Assessor and date
-
Not assessed
- Alternative assessments
-
Not assessed
- Fill
-
The makers' claim
Entry details
- Kind
-
Not assessed
- Related entries
-
Not assessed
- Field
-
Healthcare (infectious disease; sleep medicine). Consumer wearables.
- Purpose
-
Fitbit's EOV metric summarizes overnight oxygen variation for consumers. The investigators repurposed it to flag COVID-19 deterioration, and the sleep-apnea finding was incidental to that study aim.
- Dates
-
Date basis unassessed: 2021 (precision unassessed). Updated: 21 October 2026.
- Stage
-
Not assessed
- Version
-
SHA-256: 1c723e06aa36…
References
- Other identifiers
-
Not assessed
- Category mappings
-
Not assessed
- Brief
-
Not assessed
- Revisions
-
5 revisions. Latest: 21 October 2026.
Sources
-
Peer-reviewed study Developer
Yamagami K, Nomura A, Kometani M, Shimojima M, Sakata K, Usui S, Furukawa K, Takamura M, Okajima M, Watanabe K, Yoneda T (2021). Early Detection of Symptom Exacerbation in Patients With SARS-CoV-2 Infection Using the Fitbit Charge 3 (DEXTERITY): Pilot Evaluation. JMIR Formative Research 5(9):e30819 (PMC8448084).
Coincidental obstructive sleep apnea syndrome confirmed by polysomnography was detected in 1 patient via consistently high EOV signals.
We were successful in predicting exacerbation using EOV signals in 4 out of 5 cases (sensitivity=80%, specificity=90%)
His 3% oxygen desaturation index was 33.6 per hour, indicating severe OSAS.
the Fitbit wearable device, including its functions (eg, EOV) and analysis algorithms, was not yet approved as a medical device at the time of this study
Collections: Cross-border cases.