Fitbit Charge 3 signals precede 4 of 5 COVID-19 exacerbations

Kanazawa pilot, 23 COVID-19 patients (2020): Fitbit oxygen-variation signals preceded 4 of 5 exacerbations (sensitivity 80%); one man's persistent signals led to polysomnography showing severe OSAS.

AI system

System

Fitbit Charge 3 estimated oxygen variation (EOV) and resting heart rate, with investigator-defined signal thresholds

Model

Not assessed

Release

Exact release not established.

Application developer

Fitbit (device and EOV algorithm); Kanazawa University investigators (signal definitions)

Role

Not assessed

Configuration

The participant used a Fitbit Charge 3.

Inputs and outputs

Not assessed

Autonomy

Not assessed

Workflow

A Fitbit Charge 3 worn for 30 days by patients with PCR-confirmed COVID-19, giving EOV and resting heart rate. An investigator-defined high-EOV signal (a significant dip and recovery of the oxygen level within the index period) reviewed by the study team. Weekly phone calls to discharged patients and access to portable polysomnography.

Human oversight

Not assessed

Relation to AI

The device produced the EOV values. The investigators' own rule flagged high signals, and clinicians decided to order polysomnography for the sleep-apnea patient. The paper does not say whether Fitbit's EOV estimation uses machine learning and notes the functions were not approved as a medical device. The COVID-19 prediction figures were computed after the outcomes were known, not from alerts acted on in real time.

AI contribution

The device produced the EOV values. The investigators' own rule flagged high signals, and clinicians decided to order polysomnography for the sleep-apnea patient. The paper does not say whether Fitbit's EOV estimation uses machine learning and notes the functions were not approved as a medical device. The COVID-19 prediction figures were computed after the outcomes were known, not from alerts acted on in real time.

Benefits

Outcome identifiers

Not assessed

Benefit

EOV signals preceded four of five analyzed cases (sensitivity 80%, specificity 90%)

Category

Improved Physical Health

Status

Not assessed

Beneficiary groups

People. Organizations.

Beneficiaries

Not assessed

Reach

Not assessed

Distribution and access

Not assessed

Duration

Not assessed

Expected?

No

Costs and harms

Not assessed

Measurement

Studies

Not assessed

Study design

Not assessed

Measurement

Not assessed

Setting and sample

Not assessed

Measures

EOV signals preceded four of five analyzed cases (sensitivity 80%, specificity 90%)

Comparison

high resting-heart-rate (RHR) signals from the same Fitbit data

Results

Reference: the sensitivity and specificity of high RHR signals were 50% and 80%, respectively. Result: 4 out of 5 cases (sensitivity=80%, specificity=90%).

Additional value from AI

Not assessed

Limitations

Not assessed

Denominators

Not assessed

Materials for replication

Not assessed

Money

Kind of value

Not assessed

Amount

Not assessed

Currency and prices

Not assessed

Period and unit

Not assessed

Realization

Not assessed

Recipients and payers

Not assessed

Gross or net

Not assessed

Included costs

Not assessed

Comparison

Not assessed

Method

Not assessed

Return and payback

Not assessed

People and places

Participants

Developer: Fitbit (device and EOV algorithm); Kanazawa University investigators (signal definitions). Operator: Kanazawa University and JCHO Kanazawa Hospital (DEXTERITY pilot, UMIN000041421).

Jurisdictions

Benefit: Kanazawa, Japan. Developer: United States. Operator: Japan.

Ownership and control

Not assessed

Dependencies

Not assessed

Cross-border connections

Not assessed

Geopolitical implications

Not assessed

Follow-up

Conditions for replication

Patients can pair the device with a smartphone app (elderly patients unable to use a smartphone were not enrolled). Enough baseline data to separate abnormal signals from normal variation, which the authors list as lacking in the 30-day window.

Replication attempts

Not assessed

Later findings

No later DEXTERITY publication and no follow-up on patient JCHO-023 was found in the cited paper.

Availability

Not assessed

Institutional decision

Not assessed

Grounds

Not assessed

Action and result

Not assessed

Success criterion

Not assessed

Evidence

Source numbers

AIBD-0294-source-0001–0004

Citations

Numbered references below.

Language

Not assessed

Source relationships

Developer

Original evidence

Not assessed

Access and versions

Not assessed

Supported findings

Not assessed

Evidence strength

Not assessed

Missing evidence

Not assessed

Grades

Assessed benefits

People. Organizations.

Depth

People: 1. Organizations: Not assessed.

Reasons

People: One man received a diagnosis of severe obstructive sleep apnea (3% ODI 33.6/h) from an incidental wearable signal. The paper reports no treatment or follow-up for him. Organizations: The 80% sensitivity for predicting exacerbation is a retrospective pilot result on five events, which the authors say is too small to generalize. No live alerting or changed care is documented.

Observed or intended

Not assessed

Rubric

Not assessed

Assessor and date

Not assessed

Alternative assessments

Not assessed

Fill

The makers' claim

Entry details

Kind

Not assessed

Field

Healthcare (infectious disease; sleep medicine). Consumer wearables.

Purpose

Fitbit's EOV metric summarizes overnight oxygen variation for consumers. The investigators repurposed it to flag COVID-19 deterioration, and the sleep-apnea finding was incidental to that study aim.

Dates

Date basis unassessed: 2021 (precision unassessed). Updated: 21 October 2026.

Stage

Not assessed

Version

SHA-256: 1c723e06aa36…

References

Other identifiers

Not assessed

Category mappings

Not assessed

Brief

Not assessed

Revisions

5 revisions. Latest: 21 October 2026.

Sources

  1. Peer-reviewed study Developer

    Yamagami K, Nomura A, Kometani M, Shimojima M, Sakata K, Usui S, Furukawa K, Takamura M, Okajima M, Watanabe K, Yoneda T (2021). Early Detection of Symptom Exacerbation in Patients With SARS-CoV-2 Infection Using the Fitbit Charge 3 (DEXTERITY): Pilot Evaluation. JMIR Formative Research 5(9):e30819 (PMC8448084).