AI system
- System
-
IDx-DR, now sold as LumineticsCore. [1]
- Model
-
The locked diagnostic algorithms within IDx-DR. The trial does not name a separate model family or release. [1]
- Release
-
The paper and supplement do not identify the installed software release. [1]
- Provider
-
Digital Diagnostics, United States. [1]
- Role
-
The software checked image quality and assessed photographs for diabetic eye disease. [1]
- Configuration
-
The device used two retinal views and allowed up to three attempts to obtain suitable images. The trial does not name the camera model. [1]
- Inputs and outputs
-
Two color retinal photographs centered on the fovea and optic disc were assessed. The output indicated disease, no disease, or insufficient image quality. [1]
- Autonomy
-
The software produced its result without a clinician interpreting the photographs first. The research team nevertheless obtained specialist overreads for safety. [1]
- Workflow
-
Clinic staff photographed the retina during the diabetes visit. Participants received the result immediately and were referred for an eye-care visit when indicated. [1]
- Human oversight
-
A board-certified retina specialist reviewed every AI image for safety. An independent monitoring board oversaw the study. [1]
- Relation to AI
-
IDx-DR assessed retinal photographs and returned a screening result during the diabetes visit. The trial compared this on-site service with referral elsewhere. A retina specialist also reviewed the images for safety. A coauthor had financial interests in the manufacturer, although he did not have access to the underlying data.
- AI contribution
-
IDx-DR made an eye exam available at the diabetes visit. The trial tests this entire on-site service against referral elsewhere. [1]
Benefits
- Outcome identifiers
-
AIBD-0067-outcome-01 [1]
- Benefit
-
More participants completed screening when an AI eye exam was offered during their diabetes visit. [1]
- Category
-
Improved Physical Health
- Status
-
Observed in a randomized trial. [1]
- Beneficiary groups
-
People.
- Beneficiaries
-
Young people with type 1 or type 2 diabetes who were due for a diabetic eye exam. [1]
- Reach
-
All 81 AI participants and 18 of 82 controls completed screening. The 25 positive AI screens were not all confirmed diagnoses. [1]
- Distribution and access
-
The trial included a racially diverse population, and 47% of participants had Medicaid coverage. It was not large enough to establish equal effects across every subgroup. [1]
- Duration
-
Screening and referral attendance were followed for six months. [1]
- Expected?
-
Yes
- Costs and harms
-
The AI produced positive screening results that required further assessment. Its reported specificity was 78.9% against specialist review. A positive screen was not a confirmed diagnosis. [1]
Measurement
- Studies
-
NCT05131451 [1]
- Study design
-
An unmasked randomized trial, with allocation concealed until assignment. Randomization used blocks of four or six and was stratified by clinic. [1]
- Measurement
-
The primary outcome was documented completion of a diabetic eye exam within six months. Researchers also tracked referral attendance and participant satisfaction. [1]
- Setting and sample
-
The trial randomized 164 participants at two Baltimore clinics. After one control was excluded, the analysis included 81 AI participants and 82 controls. [1]
- Measures
-
Completion of a diabetic eye exam within six months, with referral attendance as a secondary outcome. [1]
- Comparison
-
Scripted education and referral to an eye-care provider, with a printed handout. [1]
- Results
-
Screening completion was 100% with AI and 22% with referral, a difference of 78 percentage points (95% CI, 69–87). [1]
- Additional value from AI
-
Randomization supports the effect of offering an immediate AI exam rather than a referral. It does not separate the algorithm from convenience and access at the clinic. [1]
- Limitations
-
The trial measured access to screening, not later vision. The referral comparison used 25 AI-positive participants versus the entire control group, so those secondary denominators are not equivalent. [1]
- Denominators
-
Participants enrolled from 24 November 2021 to 6 June 2022. Follow-up ended on 6 December 2022. An AI exam generally took five to ten minutes. [1]
- Materials for replication
-
The protocol and supplement describe the procedure. De-identified data require an approved proposal and data-use agreement. The commercial diagnostic code is not published. [1]
Money
- Kind of value
-
A gift card for study participation. This was a transfer, not value that AI created. [1]
- Amount
-
US$25 per participant, plus a parking pass whose value was not reported. [1]
- Currency and prices
-
U.S. dollars during the 2021–2022 study. No inflation adjustment was reported. [1]
- Period and unit
-
Per participant for study participation. [1]
- Realization
-
The authors report that participants received the gift card and parking pass. [1]
- Recipients and payers
-
Study participants received compensation. The article does not identify the precise paying account. [1]
- Gross or net
-
The US$25 is the face value of a gift card. It is not net benefit from screening. [1]
- Included costs
-
The article does not report the full cost of the service, specialist review, staff time, or parking passes. [1]
- Comparison
-
No comparison of financial outcomes between the randomized groups was reported. [1]
- Method
-
The source states the gift card’s face value. It does not value health outcomes. [1]
- Return and payback
-
No financial return or payback period was estimated. [1]
People and places
- Participants
-
Johns Hopkins conducted the trial at Johns Hopkins Hospital and Mount Washington Pediatric Hospital. Digital Diagnostics supplied the diagnostic product. [1]
- Jurisdictions
-
Both clinics were in Baltimore, Maryland,
United States. The manufacturer was also based in the
United States. [1] - Ownership and control
-
The reviewed clinical sources identify the organizations involved, but do not establish their complete ownership or control arrangements. [1]
- Dependencies
-
The service required a retinal camera, trained clinic staff, IDx-DR, specialist safety review, and a referral route. [1]
- Cross-border connections
-
The reviewed sources do not document international transfers of patient data or quantify cross-border financial flows. [1]
- Geopolitical implications
-
Not assessed
Follow-up
- Conditions for replication
-
The tested service combined an immediate eye exam, clinic staff, follow-up referrals, and specialist safety review for young participants. [1]
- Replication attempts
-
The reviewed sources do not report an independent repetition of this clinical result. [1]
- Later findings
-
The study followed eye-exam completion and referral attendance for six months. It did not report later vision outcomes.
- Availability
-
LumineticsCore is commercially available. The trial’s pediatric use was investigational because the FDA indication covered adults aged 22 or older. [1]
- Institutional decision
-
Johns Hopkins evaluated AI screening in young people below the device’s FDA-indicated age. [1]
- Grounds
-
The study received IRB approval, an investigational device exemption, and independent safety monitoring. [1]
- Action and result
-
Staff used the device in the trial and arranged retina-specialist review of every AI image. [1]
- Success criterion
-
The prespecified primary outcome was completion of an eye exam within six months. [1]
Evidence
- Source numbers
-
1 retained sources.
- Citations
-
Original citations and the passages that support each finding. [1]
- Language
-
English. No translation was used. [1]
- Source relationships
-
Academic investigators conducted the trial. One coauthor was an investor, director, and consultant of Digital Diagnostics, but had no access to the underlying data. [1]
- Original evidence
-
The original studies and their supporting materials are linked to the findings that they support. [1]
- Access and versions
-
Access and version details are listed for each reviewed source. [1]
- Supported findings
-
An on-site IDx-DR exam increased screening completion from 22% to 100%. [1]
- Evidence links
-
The trial flow diagram supplies the analyzed counts. Its supplement records specialist safety review. [1]
- Evidence strength
-
A peer-reviewed randomized trial by academic investigators, with a coauthor who held financial interests in the manufacturer. [1]
- Missing evidence
-
The paper does not establish later vision outcomes, the device’s exact software release, or a separate causal effect of the algorithm. [1]
Grades
- Assessed benefits
-
The benefit described here, for the beneficiary groups shown.
- Depth
-
Depth 2 for improved access to completed screening.
- Reasons
-
Depth 2 for improved access to completed screening.
- Observed or intended
-
The depth describes the reported result. Evidence strength is assessed separately.
- Rubric
-
AIBD’s five-level depth rubric, reviewed on 25 October 2026.
- Assessor and date
-
AIBD, 25 October 2026.
- Alternative assessments
-
A null grade would omit the measured improvement. Grades 3–5 would require a lasting capability or health benefit that this trial did not establish.
- Fill
-
A randomized academic evaluation with a manufacturer-affiliated coauthor. The outline is retained under the current independence rule.
Entry details
- Kind
-
A randomized trial of on-site screening versus referral. [1]
- Related entries
-
Not assessed
- Field
-
Healthcare - diabetic retinopathy screening. Autonomous AI screening in pediatric diabetes care.
- Purpose
-
IDx-DR/LumineticsCore is built to autonomously detect more-than-mild diabetic retinopathy from fundus images at the point of care. Increasing screening completion is its intended benefit.
- Dates
-
Enrollment began on 24 November 2021, and follow-up ended on 6 December 2022. [1]
- Stage
-
Investigational use in a pediatric diabetes trial. [1]
- Version
-
SHA-256: f6eae30ef3c1…
References
- Other identifiers
-
NCT05131451 [1]
- Category mappings
-
Not assessed
- Brief
-
Not assessed
- Revisions
-
7 revisions. Latest: 25 October 2026.
Sources
-
Peer-reviewed study Evaluator
Randomized screening results, denominators, age limits, procedures, and conflicts. Figure 1; Tables 1–4; Methods; Data and Code availability; Author contributions; Competing interests.
Original academic evaluation with a manufacturer-affiliated coauthor.
Supplement to the same trial. Image procedure, investigational use, and specialist safety review. Supplementary Note 3 and supplementary tables.
Supplement to the same trial.
Sponsor-supplied trial registration. Study registration and ethics identifier. Protocol identification, status, locations, eligibility, and outcomes.
Sponsor-supplied trial registration.