Coapt pattern recognition restores daily living for two amputees

Two transulnar amputees given Coapt pattern-recognition prostheses on osseointegration implants regained activities of daily living.

21ⓘ

AI system

System

Coapt pattern recognition myoelectric control (Coapt, Chicago, IL) on a multiarticulating hand and wrist

Model

Not assessed

Release

Not assessed

Application developer

Coapt LLC

Role

Not assessed

Configuration

Not assessed

Inputs and outputs

Not assessed

Autonomy

Not assessed

Workflow

Stable implanted attachment delivering consistent electrode contact. Pattern-recognition classifier trained on the patient's own EMG patterns. Structured training with the software after surgery.

Human oversight

Not assessed

Relation to AI

The Coapt software is a machine-learning pattern-recognition controller that maps electromyographic patterns to hand and wrist motions. The report attributes improved control to training with this software on an osseointegrated attachment. So the AI contribution is entangled with the surgical attachment and cannot be isolated.

AI contribution

The Coapt software is a machine-learning pattern-recognition controller that maps electromyographic patterns to hand and wrist motions. The report attributes improved control to training with this software on an osseointegrated attachment. So the AI contribution is entangled with the surgical attachment and cannot be isolated.

Benefits

Outcome identifiers

Not assessed

Benefit

Two transulnar amputees given Coapt pattern-recognition prostheses on osseointegration implants regained activities of daily living.

Category

Improved Accessibility

Status

Not assessed

Beneficiary groups

People. Society.

Beneficiaries

Not assessed

Reach

Not assessed

Distribution and access

Not assessed

Duration

Not assessed

Expected?

Yes

Costs and harms

Not assessed

Measurement

Studies

Not assessed

Study design

Not assessed

Measurement

Not assessed

Setting and sample

Not assessed

Measures

Not assessed

Comparison

direct myoelectric control

Results

Result: significant improvements in the Assessment of Capacity for Myoelectric Control (ACMC) outcome measure while using pattern recognition control compared to direct control.

Additional value from AI

Not assessed

Limitations

Not assessed

Denominators

Not assessed

Materials for replication

Not assessed

Money

Kind of value

Not assessed

Amount

Not assessed

Currency and prices

Not assessed

Period and unit

Not assessed

Realization

Not assessed

Recipients and payers

Not assessed

Gross or net

Not assessed

Included costs

Not assessed

Comparison

Not assessed

Method

Not assessed

Return and payback

Not assessed

People and places

Participants

Developer: Coapt LLC. Operator: Hospital for Special Surgery, New York (Department of Limb Lengthening and Complex Reconstruction; the affiliation is given for the first author).

Jurisdictions

Benefit: New York, New York, United States. Developer: United States. Operator: United States.

Ownership and control

Not assessed

Dependencies

Not assessed

Cross-border connections

Not assessed

Geopolitical implications

Not assessed

Follow-up

Conditions for replication

Sufficient residual muscle signals to separate grip and wrist classes. Osseointegration without loosening over the follow-up period. Clinician-supervised calibration and training.

Replication attempts

1 follow-up entries. Benefit recurred: 1.

Later findings

31 January 2023. A later randomized home-use study of transradial amputees confirmed broader grip use and better myoelectric control with Coapt pattern recognition than with direct control.

Availability

Not assessed

Institutional decision

Not assessed

Grounds

Not assessed

Action and result

Not assessed

Success criterion

Not assessed

Evidence

Source numbers

AIBD-0050-source-0001–0002

Citations

Numbered references below.

Language

Not assessed

Source relationships

Operator, Developer

Original evidence

Not assessed

Access and versions

Not assessed

Supported findings

Not assessed

Evidence strength

Not assessed

Missing evidence

Not assessed

Grades

Assessed benefits

People. Society.

Depth

People: 2. Society: 1.

Reasons

People: Two identifiable patients gained prosthetic control enough for daily living activities, documented at 18-month and 2-year follow-up. The abstract has no validated functional scores, so life-changing is unsupported. Society: A two-patient case report demonstrating feasibility of combining osseointegration with pattern-recognition control; no population-level effect shown.

Observed or intended

Not assessed

Rubric

Not assessed

Assessor and date

Not assessed

Alternative assessments

Not assessed

Fill

The deployer's account

Entry details

Kind

Not assessed

Field

Rehabilitation medicine / upper-limb prosthetics. Amputee prosthetic care.

Purpose

Pattern-recognition control of a multiarticulating myoelectric hand and wrist for people with upper-limb amputation

Dates

Date basis unassessed: 2021 (precision unassessed). Updated: 21 October 2026.

Stage

Not assessed

Version

SHA-256: a39530618e07…

References

Other identifiers

Not assessed

Category mappings

Not assessed

Brief

Not assessed

Revisions

5 revisions. Latest: 21 October 2026.

Sources

  1. Peer-reviewed study Developer

    Simon AM, Turner KL, Miller LA, Potter BK, Beachler MD, Dumanian GA, Hargrove LJ, Kuiken TA (2023). User Performance With a Transradial Multi-Articulating Hand Prosthesis During Pattern Recognition and Direct Control Home Use. IEEE Trans Neural Syst Rehabil Eng.

  2. Case report Deployer

    Jaime KM, Reif TJ, Kafedzic H, Garrison G, Dhawan J, Rozbruch SR (2021). Attachment of a Myoelectric Prosthesis After Transulnar Osseointegration Implantation: A 2-Patient Case Study. JBJS Case Connector 11(4).