Corti model beats dispatchers on sensitivity; RCT shows no gain

Copenhagen EMS call model beat dispatchers on sensitivity (84.1% vs 72.5%); RCT found no significant gain in dispatcher recognition.

AI system

System

Corti machine-learning call-analysis framework for out-of-hospital cardiac arrest recognition (the peer-reviewed papers describe it only as 'a machine learning framework'; the EENA report names Corti)

Model

Not assessed

Release

Not assessed

Application developer

Corti (Copenhagen, Denmark)

Role

Not assessed

Configuration

Not assessed

Inputs and outputs

Not assessed

Autonomy

Not assessed

Workflow

Access to recorded 112 call audio with linked outcome data (7,211 hours of Danish training data per the EENA report). Speech-recognition pipeline running in real time on live calls. A dispatch center whose baseline recognition was already high (90.5% in the control arm).

Human oversight

Not assessed

Relation to AI

The AI listened to live calls and alerted dispatchers. In the randomized trial its alerts were more sensitive than dispatchers alone (85.0% vs 77.5%). They did not significantly change dispatcher recognition (93.1% vs 90.5%, P = .15). The benefit is thus a demonstrated detection capability, not a verified change in any patient's course.

AI contribution

The AI listened to live calls and alerted dispatchers. In the randomized trial its alerts were more sensitive than dispatchers alone (85.0% vs 77.5%). They did not significantly change dispatcher recognition (93.1% vs 90.5%, P = .15). The benefit is thus a demonstrated detection capability, not a verified change in any patient's course.

Benefits

Outcome identifiers

Not assessed

Benefit

higher sensitivity than dispatchers (84.1% versus 72.5%)

Category

Improved Task Accuracy

Status

Not assessed

Beneficiary groups

People. Organizations.

Beneficiaries

Not assessed

Reach

Not assessed

Distribution and access

Not assessed

Duration

Not assessed

Expected?

Yes

Costs and harms

Not assessed

Measurement

Studies

Not assessed

Study design

Not assessed

Measurement

Not assessed

Setting and sample

Not assessed

Measures

higher sensitivity than dispatchers (84.1% versus 72.5%)

Comparison

Not assessed

Results

higher sensitivity than dispatchers (84.1% versus 72.5%)

Additional value from AI

Not assessed

Limitations

Not assessed

Denominators

Not assessed

Materials for replication

Not assessed

Money

Kind of value

Not assessed

Amount

Not assessed

Currency and prices

Not assessed

Period and unit

Not assessed

Realization

Not assessed

Recipients and payers

Not assessed

Gross or net

Not assessed

Included costs

Not assessed

Comparison

Not assessed

Method

Not assessed

Return and payback

Not assessed

People and places

Participants

Developer: Corti (Copenhagen, Denmark). Operator: Copenhagen Emergency Medical Services, Emergency Medical Dispatch Center Copenhagen.

Jurisdictions

Benefit: Copenhagen, Denmark. Developer: Denmark. Operator: Denmark.

Ownership and control

Not assessed

Dependencies

Not assessed

Cross-border connections

Not assessed

Geopolitical implications

Not assessed

Follow-up

Conditions for replication

Dispatchers act on alerts. The trial suggests alerts did not change their behavior enough to shift recognition. Call language and acoustics match the training data (EENA reports weaker performance on smaller French and Italian datasets).

Replication attempts

1 follow-up entries. Benefit recurred: 1.

Later findings

4 January 2021. The randomized trial of 169,049 calls confirmed the model's sensitivity advantage over dispatchers (85.0% vs 77.5%) but found no significant improvement in dispatcher recognition when alerts were shown (93.1% vs 90.5%).

Availability

Not assessed

Institutional decision

Not assessed

Grounds

Not assessed

Action and result

Not assessed

Success criterion

Not assessed

Evidence

Source numbers

AIBD-0030-source-0001–0003

Citations

Numbered references below.

Language

Not assessed

Source relationships

Operator, Developer

Original evidence

Not assessed

Access and versions

Not assessed

Supported findings

Not assessed

Evidence strength

Not assessed

Missing evidence

Not assessed

Grades

Assessed benefits

People. Organizations.

Depth

Not assessed

Reasons

People: The evidence is aggregate (sensitivity, time-to-recognition, trial-level recognition rates) with no individually attributable changed outcome. The randomized trial found no significant improvement in dispatcher recognition. Organizations: A capability study and a null randomized trial. No discrete organizational event with an observed outcome is documented.

Observed or intended

Not assessed

Rubric

Not assessed

Assessor and date

Not assessed

Alternative assessments

Not assessed

Fill

The deployer's account

Entry details

Kind

Not assessed

Field

Emergency medical dispatch / public safety. 112 emergency call handling.

Purpose

The model was built to recognize out-of-hospital cardiac arrest during emergency calls so dispatchers can start telephone CPR sooner. The measured capability is that intended function, but no discrete changed outcome is documented.

Dates

Date basis unassessed: 2018 (precision unassessed). Updated: 21 October 2026.

Stage

Not assessed

Version

SHA-256: daf5403a07b4…

References

Other identifiers

AI Incident Database: 446.

Category mappings

Not assessed

Brief

Not assessed

Revisions

6 revisions. Latest: 21 October 2026.

Sources

  1. Peer-reviewed study Deployer

    Blomberg SN, Christensen HC, Lippert F, et al. (2021). Effect of Machine Learning on Dispatcher Recognition of Out-of-Hospital Cardiac Arrest During Calls to Emergency Medical Services: A Randomized Clinical Trial. JAMA Network Open 4(1):e2032320.

  2. Peer-reviewed study Deployer

    Blomberg SN, Folke F, Ersboll AK, Christensen HC, Torp-Pedersen C, Sayre MR, Counts CR, Lippert FK (2019). Machine learning as a supportive tool to recognize cardiac arrest in emergency calls. Resuscitation 138:322-329. doi:10.1016/j.resuscitation.2019.01.015.

  3. Report Developer

    European Emergency Number Association and Corti (2020). Detecting out-of-hospital cardiac arrest using artificial intelligence: project report. EENA, Brussels.