AI system
- System
-
Corti machine-learning call-analysis framework for out-of-hospital cardiac arrest recognition (the peer-reviewed papers describe it only as 'a machine learning framework'; the EENA report names Corti)
- Model
-
Not assessed
- Release
-
Not assessed
- Application developer
-
Corti (Copenhagen, Denmark)
- Role
-
Not assessed
- Configuration
-
Not assessed
- Inputs and outputs
-
Not assessed
- Autonomy
-
Not assessed
- Workflow
-
Access to recorded 112 call audio with linked outcome data (7,211 hours of Danish training data per the EENA report). Speech-recognition pipeline running in real time on live calls. A dispatch center whose baseline recognition was already high (90.5% in the control arm).
- Human oversight
-
Not assessed
- Relation to AI
-
The AI listened to live calls and alerted dispatchers. In the randomized trial its alerts were more sensitive than dispatchers alone (85.0% vs 77.5%). They did not significantly change dispatcher recognition (93.1% vs 90.5%, P = .15). The benefit is thus a demonstrated detection capability, not a verified change in any patient's course.
- AI contribution
-
The AI listened to live calls and alerted dispatchers. In the randomized trial its alerts were more sensitive than dispatchers alone (85.0% vs 77.5%). They did not significantly change dispatcher recognition (93.1% vs 90.5%, P = .15). The benefit is thus a demonstrated detection capability, not a verified change in any patient's course.
Benefits
- Outcome identifiers
-
Not assessed
- Benefit
-
higher sensitivity than dispatchers (84.1% versus 72.5%)
- Category
-
Improved Task Accuracy
- Status
-
Not assessed
- Beneficiary groups
-
People. Organizations.
- Beneficiaries
-
Not assessed
- Reach
-
Not assessed
- Distribution and access
-
Not assessed
- Duration
-
Not assessed
- Expected?
-
Yes
- Costs and harms
-
Not assessed
Measurement
- Studies
-
Not assessed
- Study design
-
Not assessed
- Measurement
-
Not assessed
- Setting and sample
-
Not assessed
- Measures
-
higher sensitivity than dispatchers (84.1% versus 72.5%)
- Comparison
-
Not assessed
- Results
-
higher sensitivity than dispatchers (84.1% versus 72.5%)
- Additional value from AI
-
Not assessed
- Limitations
-
Not assessed
- Denominators
-
Not assessed
- Materials for replication
-
Not assessed
Money
- Kind of value
-
Not assessed
- Amount
-
Not assessed
- Currency and prices
-
Not assessed
- Period and unit
-
Not assessed
- Realization
-
Not assessed
- Recipients and payers
-
Not assessed
- Gross or net
-
Not assessed
- Included costs
-
Not assessed
- Comparison
-
Not assessed
- Method
-
Not assessed
- Return and payback
-
Not assessed
People and places
- Participants
-
Developer: Corti (Copenhagen, Denmark). Operator: Copenhagen Emergency Medical Services, Emergency Medical Dispatch Center Copenhagen.
- Jurisdictions
-
Benefit: Copenhagen,
Denmark. Developer:
Denmark. Operator:
Denmark. - Ownership and control
-
Not assessed
- Dependencies
-
Not assessed
- Cross-border connections
-
Not assessed
- Geopolitical implications
-
Not assessed
Follow-up
- Conditions for replication
-
Dispatchers act on alerts. The trial suggests alerts did not change their behavior enough to shift recognition. Call language and acoustics match the training data (EENA reports weaker performance on smaller French and Italian datasets).
- Replication attempts
-
1 follow-up entries. Benefit recurred: 1.
- Later findings
-
4 January 2021. The randomized trial of 169,049 calls confirmed the model's sensitivity advantage over dispatchers (85.0% vs 77.5%) but found no significant improvement in dispatcher recognition when alerts were shown (93.1% vs 90.5%).
- Availability
-
Not assessed
- Institutional decision
-
Not assessed
- Grounds
-
Not assessed
- Action and result
-
Not assessed
- Success criterion
-
Not assessed
Evidence
- Source numbers
-
AIBD-0030-source-0001–0003
- Citations
-
Numbered references below.
- Language
-
Not assessed
- Source relationships
-
Operator, Developer
- Original evidence
-
Not assessed
- Access and versions
-
Not assessed
- Supported findings
-
Not assessed
- Evidence links
-
Not assessed
- Evidence strength
-
Not assessed
- Missing evidence
-
Not assessed
Grades
- Assessed benefits
-
People. Organizations.
- Depth
-
Not assessed
- Reasons
-
People: The evidence is aggregate (sensitivity, time-to-recognition, trial-level recognition rates) with no individually attributable changed outcome. The randomized trial found no significant improvement in dispatcher recognition. Organizations: A capability study and a null randomized trial. No discrete organizational event with an observed outcome is documented.
- Observed or intended
-
Not assessed
- Rubric
-
Not assessed
- Assessor and date
-
Not assessed
- Alternative assessments
-
Not assessed
- Fill
-
The deployer's account
Entry details
- Kind
-
Not assessed
- Related entries
-
Machine listening for emergencies to alert responders: Corti flags cardiac arrest on 112 calls, while ShotSpotter's acoustic classifier missed a Durham drive-by shooting, leaving police unalerted and five victims hospitalized.
ShotSpotter Failed to Alert Authorities of Mass Shooting in North Carolina
- Field
-
Emergency medical dispatch / public safety. 112 emergency call handling.
- Purpose
-
The model was built to recognize out-of-hospital cardiac arrest during emergency calls so dispatchers can start telephone CPR sooner. The measured capability is that intended function, but no discrete changed outcome is documented.
- Dates
-
Date basis unassessed: 2018 (precision unassessed). Updated: 21 October 2026.
- Stage
-
Not assessed
- Version
-
SHA-256: daf5403a07b4…
References
- Other identifiers
-
AI Incident Database: 446.
- Category mappings
-
Not assessed
- Brief
-
Not assessed
- Revisions
-
6 revisions. Latest: 21 October 2026.
Sources
-
Peer-reviewed study Deployer
Blomberg SN, Christensen HC, Lippert F, et al. (2021). Effect of Machine Learning on Dispatcher Recognition of Out-of-Hospital Cardiac Arrest During Calls to Emergency Medical Services: A Randomized Clinical Trial. JAMA Network Open 4(1):e2032320.
Machine learning alerts alone had a significantly higher sensitivity than dispatchers without alerts for confirmed OHCA (85.0% vs 77.5%; P < .001)
-
Peer-reviewed study Deployer
Blomberg SN, Folke F, Ersboll AK, Christensen HC, Torp-Pedersen C, Sayre MR, Counts CR, Lippert FK (2019). Machine learning as a supportive tool to recognize cardiac arrest in emergency calls. Resuscitation 138:322-329. doi:10.1016/j.resuscitation.2019.01.015.
Compared with medical dispatchers, the machine learning framework had a significantly higher sensitivity (72.5% vs. 84.1%, p < 0.001) with lower specificity (98.8% vs. 97.3%, p < 0.001).
-
Report Developer
European Emergency Number Association and Corti (2020). Detecting out-of-hospital cardiac arrest using artificial intelligence: project report. EENA, Brussels.
This document is authored by EENA and Corti staff members with contributions from individual members of EENA and Corti.